(2) Brand New Siemens SGT-400 Gas Turbines (31569407) Products
Name (2) Brand New Siemens SGT-400 Gas Turbines
Code 31569407
Type Standard
Brand Siemens
Category Engines/Generators/Motors/Transmissions
subcategory Turbine
Price $9,500,000.00
Unit Each (Each)
In Stock Yes
LocationEurope
TypeBrand New
Short DescriptionUnits are from canceled project and have been stored by manufactures guidelines. Units are in excellent condition. Will come with full warranty.

(2) Brand New Siemens SGT-400 Gas Turbine

$9,500,000/each

Units are from canceled project and have been stored by manufactures guidelines. Units are in excellent condition. Will come with full warranty.

The Siemens SGT-400 Gas Turbine 50 HZ is a skid mounted gas turbine generator, producing up to 12.9MW (ISO) power, using natural gas or DF2. It has a Dry-Low NOx combustion system which reduces NOx emissions below 25ppm when running on natural gas.

These Siemens SGT-400 Gas Turbine are new and unused, still in the original packaging from Siemens. The original intended project was cancelled and they have been in secure storage since that date. These units have been in dedicated care and control by the OEM, they are stored and preserved in sealed containers in accordance with the OEM guidelines.

Provides a wide range of O&M or maintenance agreements for light industrial gas turbines, and can supply parts, controls, and other key maintenance and service items to ensure project availability.

Our long term service capability is one of the main differentiators to others who might supply secondary-market gas turbines. We stand behind this equipment with warranties and service offerings - qualities that will help ensure the success of Buyer’s project.

This proposal covers details around the scope of supply, our commercial proposal, and related information.

3.1 Supply of Siemens SGT-400 Gas Turbine Package

The Siemens SGT-400 Gas Turbine Generator is a reliable, light industrial technology gas Turbine.

Each of these Siemens SGT-400 Gas Turbine packages is complete and consists of the following;

Siemens SGT-400 Turbine BD000334/GT1/SIT/003

  • 44,200
  • 4012
  • Package

Siemens SGT-400 Generator BD000334/GT1/SIT/002

  • 36,200
  • 4430
  • Wooden crate
  • Generator cooler

Siemens SGT-400 BD000334/GT1/SIT /014

  • 500
  • 4430
  • Wooden case
  • Terminal box

Siemens SGT-400 BD000334/GT1/SIT/010

  • 200
  • 4430
  • Wooden base
  • SGT 400N Package

Siemens SGT-400 BD000334/GT1/SHE/001

  • 3,625
  • 6080
  • shrink wrapped
  • Wooden case
  • package P2 Purge Air Cooler
  • SGT-400

Siemens SGT-400 BD000334/GT1/SHE/002

  • 160
  • 5302
  • Wooden case
  • Fire extinguishing system (Haz Goods)

Siemens SGT-400 BD000334/GT1/SIT /001

  • 500
  • 5237
  • Plywood (UN) Case
  • Compressed Gas (Haz Goods)

Siemens SGT-400 BD000334/GT1/SIT/018

  • 4
  • 5236
  • Wooden case
  • Oil mist separator

Siemens SGT-400 BD000334/GT1/SIT/004

  • 600
  • 4692
  • Wooden case
  • Propane cabinet

Siemens SGT-400 BD000334/GT1/SIT/007

  • 200
  • 5361
  • Wooden case
  • Water separator

Siemens SGT-400 BD000334/GT1/SIT /009

  • 300
  • 4430
  • Wooden case
  • Coup Ii Ng. Block valve. Network

Siemens SGT-400 BD000334/GT1/SIT /008

  • 500
  • 4991
  • accessories
  • 4992
  • 5204
  • 5211
  • 6337
  • Wooden case
  • Loose material

Siemens SGT-400 BD000334/GT1/SIT/011

  • 500
  • 4011
  • Wooden case
  • Loose material

Siemens SGT-400 BD000334/GT1/SIT /012

  • 250
  • 4011
  • Wooden case
  • Loose material

Siemens SGT-400 BD000334/GT1/SIT /013

  • 600
  • 4011
  • Wooden crate
  • Electric Generator

Siemens SGT-400 BD000334/GT1/SIT /015

  • 2,300
  • 4430
  • Wooden crate
  • Bolt Box

Siemens SGT-400 BD000334/GT1/CUL/Ol

  • 7
  • 700
  • 4150
  • Pallet & Plastic
  • FH - excluding transition

Siemens SGT-400 BD000334/GT1/CUL/001

  • 2,900
  • 4150
  • Pallet & Plastic
  • 13763/02/021
  • FH Transition

Siemens SGT-400 BD000334/GT1/CUL/002

  • 1,100
  • 4150
  • Wooden crate
  • Silencer

Siemens SGT-400 BD000334/GT1/CUL/003

  • 1,200
  • 4041
  • Wooden crate
  • Cl Spool duct

Siemens SGT-400 BD000334/GT1/CUL/004

  • 175
  • 4083
  • Pallet &
  • Plastic
  • VI Filter House

Siemens SGT-400 BD000334/GT1/CUL/005

  • 780
  • 4150
  • Type of Net Package
  • Package No. (kg)
  • Wooden crate VI Bend Assembly

Siemens SGT-400 BD000334/GT1/CUL/006

  • 290 
  • 4082
  • Wooden crate VI Transition
  • Wooden crate VI Silencer
  • Wooden crate VE Outlet Bend Hood + 2x monocle plate, weather hoods
  • Wooden crate VE Silencer
  • Wooden case Vent fan
  • Pallet & Plastic CE Silencer & Transition
  • Pallet & Plastic CE Upper Stack
  • Pallet & Plastic Stack Base + Foundation
  • Embedment

Siemens SGT-400 BD000334/GT1/CU L/007

  • 160
  • 4082

Siemens SGT-400 BD000334/GT1/CUL/008

  • 390
  • 4082

Siemens SGT-400 BD000334/GT1/CU L/009

  • 250
  • 4082

Siemens SGT-400 BD000334/GT1/CUL/010

  • 350
  • 4082

Siemens SGT-400 BD000334/GT1/CU L/020

  • 625
  • 4150

Siemens SGT-400 BD000334/GT1/CUL/Oil

  • 2,950
  • 4041

Siemens SGT-400 BD000334/GT1/CU L/012

  • 2,800
  • 4041

Siemens SGT-400 BD000334/GT1/CU L/013

  • 510
  • 4041
  • Pallet & Plastic CE Upper Stack + Basalt SS

Siemens SGT-400 BD000334/GT1/CUL/014

  • 2,400
  • wired THK
  • 4041
  • Pallet & Plastic Cladding Sheet + Long Pressed

Siemens SGT-400 BD000334/GT1/CUL/015

  • 900
  • 4041, Angle 4150
  • Pallet & Plastic CE Middle stack

Siemens SGT-400 BD000334/GT1/CUL/016

  • 2,100
  • 4041
  • Wooden case Comb Exhaust Expansion joint

Siemens SGT-400 BD000334/GT1/CUL/021

  • 530
  • 4082
  • Pallet Access Platforms

Siemens SGT-400 BD000334/GT1/CUL/018

  • 770
  • 4150
  • Pallet Access steelwork

Siemens SGT-400 BD000334/GT1/CUL/019

  • 3,050
  • 4150
  • Wooden case Grade, frame

Siemens SGT-400 BD000334/GT1/CUL/022

  • 670
  • 4041
  • Wooden case Pipework bracket

Siemens SGT-400 BD000334/GT1/CUL/023

  • 825
  • 4041
  • Wooden case Installation tools

Siemens SGT-400 BD000334/GT1/SIT/005

  • 600
  • 4111
  • Wooden case installation material

Siemens SGT-400 BD000334/GT1/SIT/006

  • so
  • 4111

The Siemens SGT-400 Gas Turbine is equipped with:

  1. Gas turbine engine and generator mounted on structural steel base assembly with enclosure
  2. Generator and coupling for connection to the gas turbine engine
  3. Air inlet house and ducting
  4. Exhaust stack assembly
  5. Dual fuel system (Natural Gas & DF2)
  6. Dry-Low NOx (DLN) combustion system
  7. Lube oil filtration and cooling module
  8. Electro-hydraulic start module
  9. Integrated, modular Power Control Center (PCC)

Driven Unit. Generator

  • AC Generator, 11 kV, 3 phase, 50Hz, 4 pole, 0.8 power factor, cylindrical pole brushless type, Filter ventilated
  • Class ‘F’ insulation with class ‘F’ total temperature rise
  • Generator bearing temperature instrumentation lubricating oil piping from gas turbine to driven unit

Siemens SGT-400 Gas Turbine Package

Gas Turbine Engine

  • Core Engine - twin shaft design
  • Combustion System - Dry Low Emissions (OLE) Engine arranged for hot end drive
  • Engine bearing temperature instrumentation

Under base

Under base - fabricated carbon steel construction, arranged for multi-point mounting assemblies for the gas turbine core, auxiliary gearbox, auxiliaries, and driven unit Integral lubricating oil tank - carbon steel

Start System

Hydraulic Motor -AC electric motor driven pump

Gears, Couplings and Guards

  • Main speed reducing gearbox- epicyclic type, output shaft speed 1500 rpm Gearbox seismic vibration instrumentation
  • Auxiliary gearbox incorporating drives for start system and lubricating oil pump Drive coupling• high speed - flexible element dry type - Turbine to gearbox Drive coupling - low speed - flexible element dry type - Gearbox to AC generator Coupling guard - high speed (carbon steel) - turbine to gearbox
  • Coupling guard - low speed (carbon steel) - gearbox to driven unit

Lubricating Oil System

  • Integral mineral oil lubricating system serving the gas turbine, gearbox and driven unit Lubricating oil pump main - gas turbine gearbox driven
  • Lubricating oil pump auxiliary -AC motor driven
  • Lubricating oil pump emergency - DC motor driven
  • Lubricating oil system filter - Duplex filter, Continuous flow transfer valves, Conforms to API 614
  • Temperature and Smart type pressure & level transmitters - aluminum bodies
  • Lubricating oil tank immersion heater Lubricating oil breather oil mist eliminator Lubricating oil system cooler
  • Air blast Simplex Lubricating Oil Cooler - package roof mounted
  • Cooler Fan - single (100% duty), Suitable for a non-hazardous area Lubricating oil cooler piping supply and return - austenitic stainless steel

Gas Fuel System

  • Pilot fuel flow control system with actuator and integrated pressure transmitters Main fuel flow control system with actuator and integrated pressure transmitters Rapid-acting gas shut-off valves ( 2-off, pilot and main)
  • Temperature transmitter - aluminum body
  • Gas fuel block and vent valve assembly - off package

Liquid Fuel System

  • Low pressure fuel filter Fuel flow control valve Liquid fuel purge system Thermal relief valve
  • Liquid fuel pump, AC motor driven - Zone 2 motor
  • Temperature and Smart type pressure transmitters - aluminum bodies Block valve - Siemens standard - off package
  • Gas ignition system module - Siemens standard - off package
  • Propane start module (for stable and reliable start on liquid fuel)
  • Propane start storage bottle rack - 1 rack for all 4 turbines (bottles to be sourced locally, not included)

Acoustic Enclosure

  • Acoustic enclosure - painted carbon steel, fitted over gas turbine; gearbox and auxiliaries - BSdB(A) Doors for personnel access and maintenance, Internal lighting
  • Integral lifting beam for maintenance
  • Acoustic system transmitters - Siemens standard smart type - aluminum

Acoustic Enclosure Ventilation System

  • Ventilation air inlet filter pad type 304L stainless steel
  • Ventilation inlet and outlet dampers - 304L stainless steel - air operated Ventilation fan - single - AC electric motor driven - Zone 2
  • Ventilation air system - negative pressure
  • Ventilation air silencer - 304L stainless steel
  • Ventilation air inlet and outlet ducting- 304L stainless steel

Gas Detection System

2 - l. R. point gas detectors (vent outlet)

Fire Protection System

  • 3 - l. R. multi-spectrum flame detectors
  • 2 - Heat detectors
  • Single sounder/beacon (end of package) 1 - Beacon (inside package) Status indicator (end of package) 1 - MAC (Manual Alarm Contact) Fire Extinguishing
  • Single shot C02 fire protection system - in accordance with NFPA12 Cylinders housed in a weatherproof cabinet
  • Extinguishing system distribution pipework and nozzles

Combustion Air Inlet System

  • Combustion air filter - simple static element - painted carbon steel Combustion air filter - weather hood
  • Combustion air filter - mist eliminator
  • Combustion air filter – EPA filter stage
  • Combustion air silencer - painted carbon steel Combustion air inlet ducting - painted carbon steel

Combustion Exhaust System

  • Exhaust diffuser - ferritic stainless steel - horizontal orientation
  • Exhaust silencer - ferritic stainless steel hot section - painted carbon steel outer casing Exhaust stack - ferritic stainless steel - vertical orientation
  • Thermal insulation and aluminum cladding - personnel protection only

Package Electrical Systems

Control Panel Shelter - (Local Electrical Room)

Designed to provide environmental protection for the  Siemens SGT-400 Gas Turbine package control panels and its operators. Fully equipped with lighting, power and environmental controls consisting of:

  • 400V AC - Package Motors and Heaters supply
  • 230V 50 HZ distribution board
  • Internal and External lighting
  • Industrial 230V 50 Hz outlet
  • Air conditioning unit capable of maintaining control room at 20°C in all ambient conditions
  • The combined control panel consists of a battery charger, unit control panel for turbine and generator control and monitoring and motor control center
  • Batteries - VRLA type, sized to ensure a safe rundown of the turbine and driven unit in an emergency Package Auxiliaries
  • Turbine compressor - mobile cleaning system - 316 Stainless Steel tank- online and offline wash

    Drains Tank on package

    Auxiliary module pressure & level transmitters - Smart type - aluminum bodies

    Instrument tagging -Arrow tags - Siemens standard P&ID references Package finish suitable for onshore use

    Control System

    Package Control System Hardware

    Unit Control System section - simplex, incorporating a Siemens SIMATICPLC platform Control system located on-package

    Standard start-stop and load control functions - on-package control panel

    Operators display language - English

    Machinery vibration monitoring - Bentley Nevada 1701 system

    Ethernet TCP/IP communications data link to DCS Generator Control Panel section containing:-

  • Automatic voltage regulator
  • Synchronizing facility- automatic & manual with check synchronizer
  • Generator metering equipment and electrical protection
  • Installation and Maintenance Equipment
  • Roll-off equipment - Gas Turbine power turbine Roll-off trolley- Gas Turbine core engine removal Power turbine barring gear
  • Core lifting equipment
  • Semi-gantry crane
  • Auxiliary gearbox support

    Installation tool kit comprising of a cabinet containing common hand tools Holding down fixings - GT and driven unit package

    Holding down fixings - off-package equipment

    Selection of paints for site repairs

  • Drawings and Documentation
  • Standard set of certified information and drawings in the English language Operator manual
  • - English language - CD only

    Maintenance manual - English language - CD only

    Driven unit manual - English language - CD only

  • Spares
  • Commissioning Equipment and Tools Commissioning Spares
  • Modifications and Upgrades:
  • The following list of upgrades will be completed to these packages PRIOR to shipping, this is to ensure the units are to the latest specification and fully warranted.

  • Siemens SGT-400 Gas Turbine Item I Description

    PI604 Lub Oil Mod

    1. Lob Oil Pump with Roller bearings Auxiliary Gearbox
    2. Starter Shaft Bearing retention and sealing modification Dwell Speed Mod
    3. Software check and potential parameter change Kineton BOV Feedback.
    4. Check BOVs and replace retransmit card as necessary PIS99 Albany DC Emergency Pump Prime
    5. Lub Oil Pump Pressure Control Valve
    6. Change out of Hale Hamilton valve
    7. Batteries VRLA (not included in original package LER build).
    8. Add LER fire extinguishing hand held.
    9. I Package Documentation update

    Gas Turbine Operating Times and Maintenance History :

    1. These units have only OEM test hours on the main equipment.

    2. Expected maintenance life cycle is:

    1. Natural Gas Fuel:

    i. 4,000 operating hours to hot section inspection

    ii. 48,000 operating hours to major overhaul

    111. Daily O&M monitoring and inspections

    iv. Annual borescope and systems inspections

    2. Diesel Fuel (DF2):

    i. 12,000 operating hours to hot section inspection

    ii. 48,000 operating hours to major overhaul

    m. Daily O&M monitoring and inspections

    iv. Bi-annual borescope and system inspections

    Exclusions and Clarifications

  • Any scope not specifically listed in Section 3.1 Scope of Supply is specifically excluded.
  • Travel and living expenses are not included.
  • Onsite, personal, transit and other security is not included in the above quotation.
  • Equipment is offered with limited warranty as shown in Section S
  • Oils, filters, first fills, fuels ETC are excluded.
  • Shipping, taxes, logistics, custom duties are excluded.
  • Liquidated damages, consequential or indirect losses are excluded.
  • Conversions, modifications, other BOP excluded or covered by separate Ancillary

  • Services Agreement

  • All sales subject to prior sale Agreement which will be provided to Buyer. All transactions
  • 3.3 Additional Scope - Supply of Services
  • The following optional scope of supply is not included but can be quoted for the project.
  • Details are as follows:
  • Installation/ Startup/ Training:
  • Installation, startup, training, and commissioning services are not included in this
  • Proposal and can be offered in a separate scope proposal. The training can include onsite operator familiarization, preventive and routine maintenance activities, and more advanced troubleshooting and operator training.
  • No loadout & yard info available.

    Contact us

    Please fill out the form above to receive quote from one of our asset managers or call us toll free at 844-475-2060